EPSON Stylus CX4900/CX4905/CX5000/DX5000/DX5050/CX5900/CX6000/DX6000/DX6050 Revision A
ADJUSTMENT Adjustment Except Adjustment Program 184
11. Loosen the screw (C.B.S 3x6) for securing the Parallel Adjustment Lever
(Right).
Figure 5-18. Parallel Adjustment Lever (Right) Location
12. Set the thickness gauge at the position shown by the figure. The thickness
gauge should be placed between the front of the Paper Guide Front Unit and
the center ribs.
Figure 5-19. Placement position for thickness gauge
13. Move the Carriage Unit on the thickness gauge by using the Timing Belt, and
check whether the thickness gauge moves or not.
C A U T I O N
Do not remove a screw completely. (two or three revolution)
You need not to loosen the screw for securing the Parallel
Adjustment Lever (Light).
C.B.S 3x6
Parallel Adjustment Lever (Right)
Thickness gauge
C A U T I O N
If you push the Carriage Unit directly, it's possible to damage
the Print Head surface by the friction with the thickness gauge.
Fol
lowing is the relationship between “Parallel Adjustment
Lever (Right) operation” and “Platen gap reaction”.
Figure 5-20. Relationship between Parallel Adjustment Lever
(Right) Operation & Platen Gap
PG up (narrower)
PG down (wider)