05-2019 0073 00 31
aDjustiNg tHE coffEE grammagE
The dose adjustment lever can be posi-
tioned on one of the 10 reference notches,
whilst taking into consideration that:
-Raising the lever increases the dose;
-Lowering the lever decreases the dose;
-Each notch changes the dose by approx.
0.35 g.
To collect the dose, simply remove the
coee unit and use the appropriate "test"
menu function in "technical" mode (see the
relevant paragraph).
Important !!!
The dose that can be used is approximately
between 7 and 13.5 g; vary the degree of
grinding to slightly change the dose.
coffEE griND aDjustmENt
To vary the degree of grinding (to make it
ner or coarser), turn the grinder’s adjust-
ment knob:
-For a coarser grind, turn the knob anti-
clockwise (away from the grinders).
-For a finer grind, turn the knob clockwise
(towards the grinders).
The ner the grind, the longer the coee
will take to dispense and vice versa.
It is good practice to change the grind
neness when the coee grinder motor is
enabled.
changed, at least 2 selections need to
calibratiNg tHE milk
For models with an Evomilk cappuccino
maker only
By default, the appliance has 5 pre-cong-
ured Evomilk (prole) settings.
-
bration function when it is used for the
frotH (EmulsioN)
The percentage of air/milk to be used for
the emulsion can be set.
tEmpEraturE
The heating temperature of the milk.
EmulsioN DuratioN
The milk/air emulsion duration can be set.