X4%
= Baud rate 300*, 600*, 1200*, 1800*, 2400*, 3600*, 4800*, 7200*, 9600, 14400*, 19200,
28800*, 38400, 57600*, 115200 (default = 9600)
* Valid for serial port insert commands only
X4^
= Parity odd, even, none, mark, space (only the first letter required) (n = default)
X4&
= Data bits 7, 8
X4*
= Stop bits 1, 2
X4(
= Port timeout interval (in 10-second increments) 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
NOTE: X4$ through X4( are variables for the RS-232 inserts. These variables are repeated on page 69 as X6% through X6( and X7& for
the rear panel Remote RS-232 port.
X5) = UART starting point The starting point (X5)) is the rear panel Remote RS-232 port.
The next positions (
X5)
+1
through X5)
x
) are DTP inputs.
The next positions (X5)
x+1
through X5)
y
) are DTP outputs.
Default values: 2000 = Rear panel Remote (RS-232) port
10x8 matrix: 2001 through 2004 = input 7 through input 10
2005 through 2008 = output 5 through output 8
8x6, 8x4 matrix: 2001 and 2002 = input 7 and input 8
2003 and 2004 = output 3 and output 4
8x2 matrix: 2001 and 2002 = input 7 and 8
2003 and 2004 = output 1 and output 2