Command and Response Table for Matrix Switcher Commands (continued)
DTP CrossPoint 4K Series Matrix Switchers • Programming Guide 76
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Recall presets
NOTES:
Create presets using the DSP Configurator program (see Save a preset on page 124) and Product Configuration Software only.
If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.
Recall a global preset
X2&
. Rpr
X2&]
Command character is a period.
Example:
5.
Rpr05
]
Recall preset 5, (ties and audio settings).
Resets
Reset all global presets
E
ZG
}
Zpg
]
Clear all presets and names.
Reset one global preset
EX2&
ZG
}
Zpg
X2&]
Clear preset
X2&
and name.
System reset (factory default)
E
ZXXX
}
Zpx
]
Clear all ties and presets, restore group
masters 1 and 2.
Absolute reset, including IP settings
E
ZQQQ
}
Zpq
]
Similar to
E
ZXXX
}
, plus reset the
IP address to 192.168.254.254 and
subnet mask to 255.255.000.000.
NOTE: The absolute reset (
E
ZQQQ
}
) command resets only the switcher, not any connected DTP endpoints.
Absolute reset, excluding IP settings
E
ZY
}
Zpy
]
Similar to
E
ZQQQ
}
, but preserves IP
address, subnet mask, gateway address,
unit name, DHCP setting, and port map.
Recommended after a firmware update.
Executive modes
NOTE: See Setting the Front Panel Locks (Executive Modes) on page 48 for more information on the Lock modes.
Lock all front panel functions
1X
Exe1
]
Enable Lock mode 1.
Lock advanced front panel functions
2X
Exe2
]
Enable Lock mode 2.
Unlock all front panel functions
0X
Exe0
]
Enable Lock mode 0.
View lock status
X
X2*]
Information requests
Information request
I
DTPCP108
]
One sample response shown; different
models vary.
Request part number
N
60
-nnnn-nn
]
See the Extron website for numbers.
NOTE: There are up to three separate sets of Extron firmware on which the switcher can report: the Ethernet protocol firmware, which
handles the Ethernet interface; the switcher controller firmware, which is the overall control firmware; and the latest optional Extron
firmware update, which is available at www.extron.com.
Query controller firmware version
Q
X2(]
Example:
Q
1.23
]
The factory-installed controller firmware
version is 1.23 (sample value only).
Query controller firmware version
(verbose)
0Q
X2(
-
X3)
-
X3)]
Detailed status of the controller firmware
and any firmware upgrade. The active
firmware is marked by an asterisk (*).
A caret (^) indicates a bad checksum
or an invalid load. ?.?? indicates that
firmware is not loaded.
Response description: Ethernet protocol firmware version-switcher controller firmware version-updated firmware version
Example (DTP CrossPoint 108 4K):
0q
See below
Ethernet protocol firmware
Description
DTP CrossPoint firmware version
Updated firmware version
* indicates the version running Upload date and time
1.23-1.00(1.81LX-DTPCP108 -Fri, 31 Jul 2015 00:00:00 UTC)-1.00*(1.91LX-DTPCP108 -Fri, 25 Sep 2015 16:39:21 UTC)
NOTE:
X2&
= Preset number 0132
X2*
= Lock mode 0 = Mode 0 1 = Mode 1 2 = Mode 2 (default)
X2(
= Firmware version number to second decimal place (x.xx)
X3)
= Verbose firmware version-description-upload date and time.