Command and Response Table for Matrix Switcher Commands (continued)
DTP CrossPoint 4K Series Matrix Switchers • Programming Guide 77
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests, continued
Request system status
S
Sts00*
X3!
•
X3@
•750000•750000
]
NOTE: The “Sts00*” portion of the response appears only when the switcher is in Verbose mode 2 or 3.
Response description: Power supply
•Temperature Celsius•Future data field•Future data field
]
Example:
S
Power supply at 12.25V
Temperature is 54.0 °C
Future data fields
12.250•54.000•750000•750000
View and erase file directory
NOTE: The response to the View File Directory command differs, depending on whether the command is sent via an RS-232 or Telnet
connection or sent via a Web browser connection.
View file directory
RS-232 port and Telnet
E
DF
}
See below: List user-supplied files.
filename1•date/time•length
]
filename2•date/time•length
]
•
•
•
•
filenamen•date/time•length
]
# of•Bytes•Left
]]
View file directory
Web browser
E
DF
}
See below: List user-supplied files.
Var•file•=•new•array•();
File
•[1]•=•‘filename1,date1,filesize1‘;
File
•[2]•=•‘filename3,date3,filesize3‘;
•
•
•
•
File•[n]•=•‘filenamen,daten,filesizen‘;
File
•[n+1]•=•# of•Bytes•Left
Erase user-supplied Web page/files
E
filenameEF
}
Del•filename
]
Scaler Commands
Brightness
Set a specific brightness value
EX$
*
X3#
BRIT
}
Brit
X$
*
X3#]
Specify the brightness adjustment.
Increment brightness value
EX$
+BRIT
}
Brit
X$
*
X3#]
Increase the brightness setting by one.
Decrement brightness value
EX$
–BRIT
}
Brit
X$
*
X3#]
Decrease the brightness setting by one.
View the brightness value
EX$
BRIT
} X3#]
Show the brightness setting.
Contrast
Set a specific contrast value
EX$
*
X3#
CONT
}
Cont
X$
*
X3#]
Specify the contrast adjustment.
Increment contrast value
EX$
+CONT
}
Cont
X$
*
X3#]
Increase the contrast setting by one.
Decrement contrast value
EX$
–CONT
}
Cont
X$
*
X3#]
Decrease the contrast setting by one.
View the contrast value
EX$
CONT
} X3#]
Show the contrast setting.
Detail
Set a specific detail value
EX!
*
X3#
HDET
}
Hdet
X!
*
X3#]
Specify the detail adjustment.
Increment detail value
EX!
+HDET
}
Hdet
X!
*
X3#]
Increase the detail setting by one.
Decrement detail value
EX!
–HDET
}
Hdet
X!
*
X3#]
Decrease the detail setting by one.
View the detail value
EX!
HDET
} X3#]
Show the detail setting.
NOTE:
X! = TP (scaled) and insertion output number See X! definition on page 69 for numbers by matrix size.
X$
= Input number
01 – the highest numbered input for your model
X3!
= Voltage Positive or negative voltage and magnitude
X3@
= Internal temperature Degrees Celsius
X3# = Picture adjustments 000 through 127 (064 = default)