5 Conversion and maintenance
112 Festo P.BE-MPA-EN 1309f English
Mounting
Proceed as follows:
1. Check the exposed seals for damage. Replace damaged seals.
2. Place the seal onto the guide pins of the sub-base or air supply plate.
1
2
1
1 Guide pins 2 Seal (opt ional separating seal for pressure
zone separation)
Fig. 5.7 Sub-base mounting