Assembly
5.5 Connecting components
74 Edition 06/2022 A5850-02en
2. Mount the system on the gear unit in accordance with the dimension drawings in the
complete documentation, or install it as a separate system.
3. Avoid distorting the piping when installing.
Further information
You can find additional information on the oil supply system in the operating instructions of
the oil supply system, which are part of the complete documentation of the gear unit.
5.5.4 Connecting the heating element5.5 Connecting components
Procedure
To connect heating elements to the gear unit, proceed as follows:
1. Check that the heating element connection is not damaged.
2. Install the electrical wiring for the heating elements.
Further information
You can find additional information about the heating in the heating operating instructions in
the complete documentation for the gear unit.
5.5.5 Connecting the Pt 100 resistance thermometer5.5 Connecting components
Procedure
To connect the Pt 100 resistance thermometer, proceed as follows:
1. Check that the Pt 100 resistance thermometer connection is not damaged.
2. Install the electrical wiring between the Pt 100 resistance thermometer and the evalu-
ation unit. The customer is responsible for providing the evaluation unit.
Further information
Further information about the Pt 100 resistance thermometer can be found in the Pt100 res-
istance thermometer operating instructions in the complete documentation for the gear unit.