EasyManua.ls Logo

FLENDER K.SH - Commissioning; Measures Prior to Commissioning; Gear Unit with Cooling Coil

FLENDER K.SH
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A5850-02en Edition 06/2022 81
Commissioning
6
6.1 Measures prior to commissioning6.1 Measures prior to commissioning
Take the following measures before commissioning the gear unit:
Read and observe the operating instructions.
Replace the screw plug with the air filter or the wet-air filter. Note the instructions 7300
for this.
Fill the gear unit with oil.
Gear unit with oil supply system: Check that the oil supply system is working properly.
Check the oil level.
Check the gear unit for leaks.
Check whether the monitoring devices are connected and switched on.
Gear unit with oil supply system: Take the appropriate measures before commissioning
gear units with an oil supply system (Page82).
Ensure that all pipes and components are filled with oil.
More information
You can find additional information on oil and changing the air filter in the instructions 7300,
which are part of the complete documentation of the gear unit.
More information about individual components can be found in the operating instructions for
the components in the complete documentation for the gear unit.
6.1.1 Gear unit with cooling coil6.1 Measures prior to commissioning
Take the following measures before commissioning the gear unit with cooling coil:
Check that connecting pipes are firmly seated and tight.
Open wide the shutoff valves in the coolant inflow and outflow lines of the coolant sys-
tem.
Make sure that the pressure in the cooling coil does not exceed the maximum permiss-
ible pressure.
Make sure that the temperature of the cooling water is not higher than the maximum per-
missible value.
Further information
You can find additional information on the cooling coil in the data sheet and the list of equip-
ment, which are part of the complete documentation of the gear unit.
You can find additional information on connection dimensions and cooling water parameters
in the dimensional drawing of the gear unit, which is part of the complete documentation of
the gear unit.