Operation
7.3 Taking the unit out of service
86 Edition 06/2022 A5850-02en
Rectifying irregularities in operation
Proceed as follows to rectify any irregularities in operation:
1. Switch off the drive assembly if it exhibits irregular behaviour during operation.
2. Refer to the Fault information (Page91) to find the cause of the fault.
3. If you still cannot determine the fault cause, contact FlenderCustomer Services
(Page95).
7.3 Taking the unit out of service7.3 Taking the unit out of service
If you take the unit out of service for a prolonged period, you must take the following meas-
ures depending on the length of time that the gear unit will remain out of service:
• Switch off the drive aggregate.
• For gear units with a cooling coil or a water-oil cooler:
– Drain the water out of the cooling coil or the water-oil cooler if there is a risk of frost.
– Close the shutoff valves for the cooling water inlet and drain lines.
• For gear units with an oil supply system, perform the following steps before you preserve
the gear unit:
– Detach the connection between the oil supply system and the gear unit.
– Seal the openings in the gear unit and oil supply system so that they are air-tight.
• Take measures to preserve the gear unit if it is to be out of service for a prolonged
period. Follow the procedure described in instructions7300.