A5850-02en Edition 06/2022 85
Operation
7
7.1 Operating data7.1 Operating data
Introduction
To ensure correct, trouble-free operation of the system, observe the operating data of the
gear unit and, depending on the order specification, the data in the operating instructions for
the oil supply system.
The valid operating data can be found in the annex Technical data (Page103).
The following operating data apply to the oil:
Maximum operating temperat-
ure
90°C is applicable for mineral oil, API groups I or II and satur-
ated synthetic ester
Maximum operating temperat-
ure
100°C is applicable for semi-synthetic oils, API group III, PAO
and PG oils
Oil pressure of the oil supply
system
>0.5bar
Water pressure in the cooling
coil
<8.0bar
Table7-1: Operating data
Further information
You will find further information on the technical data of the gear unit in the data sheet and
the list of equipment, which are part of the complete documentation of the gear unit.
7.2 Irregularities in operation7.2 Irregularities in operation
Introduction
Switch off the drive assembly immediately if it exhibits irregular behaviour during operation.
A few irregularities are listed below as examples:
Oil temperature exceeds the maximum permissible value
Alarm tripped by the pressure monitor in the oil cooling system or oil supply system
Unusual operating noise
NOTICE
Faults can cause damage to the gear unit
The gear unit might sustain damage if it is not shut down when a fault occurs.
Switch off the drive assembly immediately if any fault condition develops.