5.6.6. GW Get Data String (Net, Gross & Status) ................................................................ 45
5.6.7. GA Get Triggered Average Value .............................................................................. 46
5.6.8. GL Get Data String (Average, Gross & Status) .......................................................... 46
5.6.9. OF Output Format for Data String GW & GL .............................................................. 46
5.6.10. GH Get Hold Value ................................................................................................ 47
5.6.11. TH Trigger Hold Value ........................................................................................... 47
5.6.12. GM Get Peak Value ............................................................................................... 47
5.6.13. RM Reset Peak Value ............................................................................................ 47
5.6.14. GO Get Peak-to-Peak Value .................................................................................. 48
5.6.15. GV Get Valley Value .............................................................................................. 48
5.6.16. HW Hold Weight .................................................................................................... 48
5.7. AutoTransmit Commands SG, SN, SX, SMV, SA, SL, SW ....................................... 49
5.7.1. SG Send Gross Value Continuously .......................................................................... 49
5.7.2. SN Send Net Value Continuously .............................................................................. 49
5.7.3. SX Send ADC Sample Value Continuously ............................................................... 49
5.7.4. SMV Send mV/V Sample Value Continuously ........................................................... 49
5.7.5. SA Send Triggered Average Value Continuously ....................................................... 49
5.7.6. SL Send Data String Continuously (Average, Gross & Status) .................................. 50
5.7.7. SW Send Data String Continuously (Net, Gross & Status) ......................................... 50
5.8. Commands for External I/O Control IN, OM, IO ......................................................... 51
5.8.1. IN Read Status of Logic Inputs .................................................................................. 51
5.8.2. OM Control of Logic Outputs by Host Application ...................................................... 51
5.8.3. IO Read/Modify Status of Logic Outputs .................................................................... 51
5.9. Set-Point Output Commands S’n’, H’n’, A’n’, HT ....................................................... 53
5.9.1. S‘n’ Set-Point Value ................................................................................................... 53
5.9.2. H’n’ Hysteresis & Switching Action for Set-Point ........................................................ 53
5.9.3. A’n’ Source Allocation for Set-Point ........................................................................... 54
5.9.4. HT Hold-Time for All Set-Points ................................................................................. 54
5.10. Communication Setup Commands AD, NA, NS, BR, DX, CL, OP, TD, CTR, STR,
SBR 55
5.10.1. AD Device Address Serial Channel ..................................................................... 55
5.10.2. NA Network Address CANopen ........................................................................... 55
5.10.3. NS Network Settings CANopen ........................................................................... 55
5.10.4. BR Baud-Rate Serial Channel ............................................................................. 56
5.10.5. DX Full-Duplex Serial Channel ............................................................................ 56
5.10.6. CL Close Device Address ‘n’ .................................................................................. 56
5.10.7. OP Open Device .................................................................................................... 56