EasyManua.ls Logo

Fluke DSX-600 - Page 63

Fluke DSX-600
238 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3: Certify Twisted Pair Cabling
The DSX-600 CableAnalyzer Home Screen
45
Shows a summary of the test results in the project:
The number of tests that passed.
The number of tests that failed.
The number of results from tests on twisted pair cable that
have PASS* results. PASS* results have measurements within
the range of accuracy uncertainty for the tester. See “PASS*/
FAIL* Results” on page 58.
The test setup panel shows the settings the tester will use when
you tap TEST or press . To change these settings, tap the
panel.
Icons show the status of the Store Plot Data and AC Wire Map
settings. See Table 2 on page 51.
Next ID: The Next ID panel shows the ID that the tester gives to
the next test results you save.
Tap Next ID to do these tasks:
Enter an ID, select a different ID in the ID set, select a
different set of IDs, or make a new set. The tester adds the
IDs and ID sets you make to the project that shows on the
home screen.
Turn Auto Save on or off.
Operator: The name of the person who does the job. You can
enter a maximum of 20 operator names. For each operator you
can also enter the email address that the operator will use as an
ID to sign in to LinkWare Live.
TOOLS: The TOOLS menu lets you set the reference, see the
status of the tester, and set user preferences such as the
language and the display brightness.
RESULTS: Tap RESULTS to see and manage the results that are
saved in the tester.

Table of Contents