104
Setting menu
item ‘DATCOM
(continued)
‘PDCDDONE’ ...
... or ...
‘IFCDDONE’ is shown
5. Press the ‘Esc’ key 2x to exit
menu item ‘DAT
COM
Data connection faulty or an option is not installed
If there is a faulty data connec-
tion or options are not installed
‘ERRORCOM’ is shown.
3. Press the ‘Esc’ key to exit menu
item ‘DATCOM
Setting menu
item ‘TIME’
1. Select menu item ‘TIME’
2. Press the ‘Enter key
The date is shown
(DD.MM.YYYY), the first digit
for the day flashes
3. Use the ‘Up’ and ‘Down’ keys to
select a value for the first day
digit
4. Press the ‘Enter key
The second day digit flashes
5. Use the ‘Up’ and ‘Down’ keys to
select a value for the second
day digit
6. Press the ‘Enter key

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus 3.0-1 and is the answer not in the manual?

Fronius IG Plus 3.0-1 Specifications

General IconGeneral
Protection classIP 44
Max. output current13 A
Nominal AC voltage230 V
THD< 3%
Max. DC voltage500 V
Maximum Input Voltage500 V
Number of MPP Trackers1
Operating Temperature Range-20°C to +55°C
CoolingConvection
Warranty5 years
AC nominal output3000 W
Max. apparent AC power3000 VA
AC voltage range180 - 264 V