91
Scrolling
among menu
items
(1) (2) (1) (2)
STANDBY
Manual activation / deactivation of Standby operation using the ‘Enter key
Unit -
Setting range Enter
Factory setting ‘Standby’ deactivated
- During standby operation the electronic system of the power stage is
switched off. No power is fed into the grid.
- The Operating status LED flashes orange.
- The orange flashing Operating Status LED stops at dusk.
- After the subsequent sunrise, the power supply operation into the grid
is resumed automatically (after completion of the startup phase the
LED is illuminated green).
- Grid supply operation can be resumed at any time whenever the LED
is flashing orange (deactivate ‘STANDBY’)
CONTRAST
set contrast on LCD display
Unit -
Setting range 0 - 7
Factory setting 7
Since contrast depends on temperature, it may be necessary to adjust the
menu item ‘Contrast’ when ambient conditions change
Menu Items in
the Setup
Menu
1. Open the setup menu
2. Scroll among the available menu items using the ‘Up’ (1) and ‘Down’
(2) keys
Example: menu item ‘STANDBY
Example: menu item ‘CONTRAST

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus 3.0-1 and is the answer not in the manual?

Fronius IG Plus 3.0-1 Specifications

General IconGeneral
Protection classIP 44
Max. output current13 A
Nominal AC voltage230 V
THD< 3%
Max. DC voltage500 V
Maximum Input Voltage500 V
Number of MPP Trackers1
Operating Temperature Range-20°C to +55°C
CoolingConvection
Warranty5 years
AC nominal output3000 W
Max. apparent AC power3000 VA
AC voltage range180 - 264 V

Related product manuals