92
LIGHTMODE
pre-setting of display illumination.
Unit -
Setting range AUTO / ON / OFF
Factory setting AUTO
AUTO: The display illumination will stop 30 seconds after the last time
a key has been pressed
ON: The display will remain illuminated whenever power is supplied
to the grid
OFF: The display illumination will be permanently off.
Important These instructions are only applicable for the display back-
ground illumination. The LCD display will still remain on during operation.
Its energy consumption is less than one mW (1/1000 W).
CASH
setting of currency and rate for invoicing the energy supplied
Unit -
Display area Currency / Charge rate/kWh
Factory setting USD
CO
2
setting of CO
2
reduction factor
Unit lb/kWh or T/kWh
Display area 00.01 - 99.99
Factory setting 1.3 lb/kWh
YIELD
setting of
- an OFFSET value for the Total energy display
- a measurement correction value for the Day, Year and Total energy
display
Unit -
Display area OFFSET / CALI.
Factory setting -
OFFSET Preset value for the energy supplied, added to the actual ener-
gy supplied (e.g. transfer value at the exchange of the inverter)
Display area: 5 digits + SI prefix (k..., M...)
CALI. Preset correction value, so that the data shown on the inverter
display corresponds to the calibrated data shown on the elec-
tric meter
Display area: -5.0 - +5.0 % in steps of 0.1
Menu Items in
the Setup
Menu
(continued)