Relevant Standards and Directives
Grid Failure
Relevant Stan-
dards and
Directives
- UL 1741-2005
- IEEE 1547-2003
- IEEE 1547.1
- ANSI/IEEE C62.41
The standard measurement and safety procedures integrated into the
Fronius IG Plus ensure that the power feed is immediately interrupted in
the event of a grid failure (shut-off by the utility or damage to lines).
- FCC Part 15 A & B
- NEC Article 690
- C22. 2 No. 107.1-01
(September 2001)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus 3.0-1 and is the answer not in the manual?

Fronius IG Plus 3.0-1 Specifications

General IconGeneral
Protection classIP 44
Max. output current13 A
Nominal AC voltage230 V
THD< 3%
Max. DC voltage500 V
Maximum Input Voltage500 V
Number of MPP Trackers1
Operating Temperature Range-20°C to +55°C
CoolingConvection
Warranty5 years
AC nominal output3000 W
Max. apparent AC power3000 VA
AC voltage range180 - 264 V