122
403
EEPROM faulty
Behavior If it is possible, your Fronius IG Plus unit will resume
the power feeding operation after successfully com-
pleting another attempt to connect
Remedy If status code persists, you should contact a Fronius-
trained service technician
406
AC temperature sensor faulty
Behavior Fronius IG Plus disconnects from the grid for safety
reasons
Remedy If status code persists, you should contact a Fronius-
trained service technician
407
DC temperature sensor faulty
Behavior Fronius IG Plus disconnects from the grid for safety
reasons
Remedy If status code persists, you should contact a Fronius-
trained service technician
408
Direct current feed in
Behavior Fronius IG Plus disconnects from the grid for safety
reasons
Remedy If status code persists, you should contact a Fronius-
trained service technician
412
The setting “fixed voltage“ has been selected instead of the MPP-voltage
operation and the voltage is set to too low a value, or DC voltage exceeds
allowable limits.
Behavior Fixed voltage lower than the current MPP-voltage
Remedy If status code persists, you should contact a Fronius-
trained service technician, or remove excess modules
so DC voltage fits within inverter limits.
413
Control problems
Behavior The Fronius IG Plus briefly disconnects from the grid,
if AC voltage or frequency are out of range
Remedy If status code persists, you should contact a Fronius-
trained service technician
414
EEPROM faulty
Behavior Memory deleted
Remedy If status code persists, you should contact a Fronius-
trained service technician
Class 4 Status
Codes
(continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus 3.0-1 and is the answer not in the manual?

Fronius IG Plus 3.0-1 Specifications

General IconGeneral
Protection classIP 44
Max. output current13 A
Nominal AC voltage230 V
THD< 3%
Max. DC voltage500 V
Maximum Input Voltage500 V
Number of MPP Trackers1
Operating Temperature Range-20°C to +55°C
CoolingConvection
Warranty5 years
AC nominal output3000 W
Max. apparent AC power3000 VA
AC voltage range180 - 264 V