3
Contact our After-Sales Service team with a detailed description of the error
ESr | 20
The cooling unit used is not compatible with the power source
Connect compatible cooling unit
Cause:
Remedy:
-----
An invalid welding process was called up on the robot interface (no.
37) or an empty flag was selected (no. 32)
Call up a valid welding process or select assigned "Save" button
Cause:
Remedy:
ELn | 8
The connected wirefeeder is not supported
Connect supported wirefeeder
Cause:
Remedy:
ELn | 12
Different control panels for selecting materials are in the system
Connect similar control panels to select materials
Cause:
Remedy:
ELn | 13
Impermissible change of welding process during welding
During welding do not make any impermissible change to the welding
process, reset error message by pressing any button
Cause:
Remedy:
ELn | 14
More than one robot interface is connected
Only one robot interface may be connected, check the system config-
uration
Cause:
Remedy:
ELn | 15
More than one remote control is connected
Only one remote control may be connected, check the system config-
uration
Cause:
Remedy:
ELn | 16
Wirefeeder program selector not compatible
A wirefeeder with standard program selector is connected to the
pulse power source
Connect wirefeeder with pulse program selector
Cause:
Remedy:
Err | IP
The power source control has detected a primary overvoltage
Check the grid voltage.
If the service code persists, switch off the power source, wait for 10
seconds and then switch the power source on again.
If the error still persists, contact the After-Sales Service team
Cause:
Remedy:
112