Corrections dur-
ing welding
To obtain the best possible welding results, the arc-force dynamic parameter will
sometimes need to be adjusted.
1
Press the "Parameter selection" button to select the arc-force dynamic para-
meter
2
Use the selection dial to set the desired arc-force dynamic value
The welding parameter value is shown in the digital display located above it.
To influence the short-circuiting dynamic at the instant of droplet transfer:
- = hard, stable arc
0 = neutral arc
+ = soft, low-spatter arc