Commissioning
Safety
WARNING!
An electric shock can be fatal.
If the power source is connected to the grid during installation, there is a danger
of serious personal injury and property damage.
Only carry out work on the device when the power source's power switch is in
the - O - position.
Only carry out work on the device when the power source has been discon-
nected from the grid.
WARNING!
Danger of electrical current due to electrically conductive dust in the device.
This can result in severe personal injury and damage to property.
Only operate the device if an air filter is fitted. The air filter is a very import-
ant safety device for achieving IP 23 protection.
General Commissioning is described with reference to a manual, water-cooled MIG/MAG
application.
Information on
system compon-
ents
The steps and activities described below include references to various system
components, such as
-
Trolley
-
Upright bracket
-
Cooling units
-
Wirefeeders
-
Interconnecting hosepacks
-
Welding torches, etc.
For more detailed information about installing and connecting the system com-
ponents, please refer to the appropriate Operating Instructions for the system
components.
51
EN-US

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 5000 Pulse and is the answer not in the manual?

Fronius TransSteel 5000 Pulse Specifications

General IconGeneral
BrandFronius
ModelTransSteel 5000 Pulse
CategoryWelding System
LanguageEnglish

Related product manuals