Setting range: 2T (2-step), 4T (4-step)
Factory setting: 2T (2-step)
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds
to restore the factory settings
- when "PrG" appears on the digital display, the power source has been re-
set
IMPORTANT! If the power source is reset, all the personal settings in the
Setup menu are lost.
Operating points stored using save buttons remain stored when the power
source is reset. The functions in the second level of the setup menu (2nd)
are also not deleted. Exception: Ignition time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup Menu 2nd Level")
Setup paramet-
ers for MMA
welding
IMPORTANT! When resetting the power source using the Factory FAC setup
parameter, the hot current time (Hti) and HotStart current (HCU) setup paramet-
ers are also reset.
HCU HotStart current
Unit: %
Setting range: 100 - 200
Factory setting: 150
Hti Hot current time
Unit: s
Setting range: 0 - 2.0
Factory setting: 0.5
ASt Anti-stick
Unit: -
Setting range: On, OFF
Factory setting: OFF
AAG Gouging (Arc Air Gauging)
Arc air gouging with a carbon electrode, e.g., for joint preparation
Unit: -
Setting range: on / OFF
Factory setting: oFF
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds
to restore the factory settings - when "PrG" appears on the digital display,
the power source has been reset.
IMPORTANT! If the power source is reset, all the personal settings are
lost.
Operating points stored using save buttons are not deleted when the
power source is reset - they remain stored. The functions in the second
level of the setup menu (2nd) are also not deleted. Exception: Ignition
time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup Menu 2nd Level")
99
EN-US