WARNING!
Danger of electrical current due to electrically conductive dust in the device.
This can result in severe personal injury and damage to property.
▶
Only operate the device if an air filter is fitted. The air filter is a very import-
ant safety device for achieving IP 23 protection.
The ventilation channel is a very important safety device. When selecting the
setup location, ensure that the cooling air can enter or exit unhindered through
the vents on the front and back. Any electrically conductive dust (e.g., from
grinding work) must not be allowed to be sucked into the device.
Grid Connection The devices are designed for the grid voltage stated on the rating plate. If the
mains cable or mains plug has not been attached to your version of the appli-
ance, these must be installed according to national standards. Fuse protection
for the grid lead can be found in the technical data.
CAUTION!
Danger due inadequately dimensioned electrical installations.
This can lead to serious damage
▶
The grid lead and its fuse protection should be designed to suit the existing
power supply.
The technical data on the rating plate should be followed.
45
EN-US