no | H2O
Coolant flow rate too low
Check coolant flow rate and cooling unit, including cooling circuit
(for minimum coolant flow, see "Technical Data" chapter in the Oper-
ating Instructions for the device)
Cause:
Remedy:
hot | H2O
The coolant temperature is too high
Allow cooling unit and cooling circuit to cool down, until "hot | H2O"
is no longer displayed. Open the cooling unit and clean the cooler,
check fan is working properly.
Cause:
Remedy:
no | Prg
No preconfigured program has been selected
Select a configured program
Cause:
Remedy:
no | IGn
"Ignition time-out" function is active; current did not start flowing
before the length of wire specified in the Setup menu had been fed.
The power source safety cut-out has tripped
Shorten the wire stick-out; press the torch trigger again; clean the
surface of the workpiece; if necessary, set the "Ito" parameter in the
Setup menu
Cause:
Remedy:
EPG | 17
The selected welding program is invalid
Select a valid welding program
Cause:
Remedy:
EPG | 29
The required wirefeeder is not available for the selected characterist-
ic
Connect the correct wirefeeder, check the plug connections for the
hosepack
Cause:
Remedy:
EPG | 35
Measurement of the welding circuit resistance failed
Check grounding cable, current cable, or hosepack and replace if ne-
cessary, re-measure the welding circuit resistance
Cause:
Remedy:
Displayed ser-
vice codes in
connection with
OPT Easy Docu-
mentation
no | dAt
Welding is not possible
Date and time are not set on the power source
To reset the service code, press the arrow key;
Set date and time in the 2nd level of the service menu:
see page 91
Cause:
Remedy:
bAt | Lo
Welding is possible
The battery of OPT Easy Documentation is low
To reset the service code, press the arrow key;
Contact service (to change the battery)
Cause:
Remedy:
116

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 5000 Pulse and is the answer not in the manual?

Fronius TransSteel 5000 Pulse Specifications

General IconGeneral
BrandFronius
ModelTransSteel 5000 Pulse
CategoryWelding System
LanguageEnglish

Related product manuals