EFd | 81, EFd | 83
Fault in the wirefeed system (overcurrent in wirefeeder drive)
Arrange the hosepack in as straight a line as possible; check that
there are no kinks or dirt in the inner liner; check the contact pres-
sure on the 4 roller drive
Wirefeeder motor is sticking or faulty
Check the wirefeeder motor or contact the After-Sales Service team
Cause:
Remedy:
Cause:
Remedy:
to0 | xxx
Note: xxx stands for a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down, check air filter and clean if neces-
sary, check that fan is on
Cause:
Remedy:
to1 | xxx
Note: xxx stands for a temperature value
Overtemperature on the booster located in the power source
Allow power source to cool down, check air filter and clean if neces-
sary, check that fan is on
Cause:
Remedy:
to2 | xxx
Note: xxx stands for a temperature value
Overtemperature in the secondary circuit of the power source
Allow power source to cool down, check that fan is on
Cause:
Remedy:
to3 | xxx
Note: xxx stands for a temperature value
Overtemperature in wirefeeder motor
Allow wirefeeder to cool down
Cause:
Remedy:
to4 | xxx
Note: xxx stands for a temperature value
Overtemperature in welding torch
Allow welding torch to cool down
Cause:
Remedy:
to5 | xxx
Note: xxx stands for a temperature value
Overtemperature in cooling unit
Allow cooling unit to cool down, check that fan is on
Cause:
Remedy:
to6 | xxx
Note: xxx stands for a temperature value
Overtemperature on the power source transformer
Allow power source to cool down, check air filter and clean if neces-
sary, check that fan is on
Cause:
Remedy: