To set the date and time:
-
Left-hand selection dial:
select parameter
-
Right-hand selection dial:
change values
Setting ranges:
yEA Year (20yy; 0 - 99)
Mon Month (mm; 1 -1 12)
dAY Day (dd; 1 - 31)
Hou Hour (hh; 0 - 24)
Min Minute (mm; 0 - 59)
NOTE!
If the power source is reset to factory settings via setup parameter FAC, the
date and time remain stored.
Deactivating
Easy Document-
ation
CAUTION!
Risk of data loss or data damage due to premature disconnection of the USB
thumb drive
Do not disconnect the USB thumb drive until approx. 10 seconds after the
end of the last welding operation to ensure correct data transfer.
1
Unplug the USB thumb drive from the power source
The power source display shows:
Easy Documentation is deactivated.
2
Acknowledge the display by pressing the arrow key