MHT260a (Engl.)
6-33
(3) T-link
(a) System parameter 1 to 21, 56 to 59
Para. Name Setting range Initial value Change
01 CONT1 signal assignment 0 to 55 (in 1 step) 0 Power
02 CONT2 signal assignment 0 to 55 (in 1 step) 0 Power
03 CONT3 signal assignment 0 to 55 (in 1 step) 0 Power
04 CONT4 signal assignment 0 to 55 (in 1 step) 0 Power
05 CONT5 signal assignment 0 to 55 (in 1 step) 0 Power
06 CONT6 signal assignment 0 to 55 (in 1 step) 0 Power
07 CONT7 signal assignment 0 to 55 (in 1 step) 0 Power
08 CONT8 signal assignment 0 to 55 (in 1 step) 0 Power
09 CONT9 signal assignment 0 to 55 (in 1 step) 1 Power
10 CONT10 signal assignment 0 to 55 (in 1 step) 4 Power
11 CONT11 signal assignment 0 to 55 (in 1 step) 2 Power
12 CONT12 signal assignment 0 to 55 (in 1 step) 3 Power
13 CONT13 signal assignment 0 to 55 (in 1 step) 5 Power
14 CONT14 signal assignment 0 to 55 (in 1 step) 10 Power
15 CONT15 signal assignment 0 to 55 (in 1 step) 11 Power
16 CONT16 signal assignment 0 to 55 (in 1 step) 12 Power
17 CONT17 signal assignment 0 to 55 (in 1 step) 13 Power
18 CONT18 signal assignment 0 to 55 (in 1 step) 7 Power
19 CONT19 signal assignment 0 to 55 (in 1 step) 51 Power
20 CONT20 signal assignment 0 to 55 (in 1 step) 16 Power
21 CONT21 signal assignment 0 to 55 (in 1 step) 0 Power
56 CONT22 signal assignment 0 to 55 (in 1 step) 0 Power
57 CONT23 signal assignment 0 to 55 (in 1 step) 0 Power
58 CONT24 signal assignment 0 to 55 (in 1 step) 0 Power
59 CONT25 signal assignment 0 to 55 (in 1 step) 0 Power
Function (input signal) number assigned to Function (output signal) assigned to
system para. 1 to 21 (CONT1 to CONT21) system para. 31 to 51 (OUT1 to OUT21)
system pwa. 56 to 59 (CONT22 to CONT25)
0: Not assigned 33: Clamping end 0: Not assigned 34: Alarm code 2
1: Run command [RUN] 34: External fault input 1: Ready [RDY] 35: Alarm code 3
2: Forward command [FWD] 42: 2nd origin 2: Indexing end [WPSET] 36: Alarm code 4
3: Reverse command [REV] 43: Override valid 13: Rewrite end 40: Origin LS detection
4: Auto start [START] 44: Override 1 14: Brake timing 41: Forced stop detection
5: Origin return [ORG] 45: Override 2 15: Dynamic braking 60: PD0
6: Origin LS [LS] 46: Override 4 16: Alarm detection 61: PD1
7: DIR 47: Override 8 17: Fixed point 1 62: PD2
9: ABS/INC 48: Manual index select 0 18: Fixed point 2 63: PD3
10: Forced stop [EMG] 49: Manual index select 1 22: Origin return end 64: PD4
11: Alarm reset [RST] 50: Deviation clear 23: Deviation zero 65: PD5
12: VEL0 51: X1 24: Speed zero 66: PD6
13: VEL1 52: X2 25: Speed arrive 67: PD7
14: ACC0 53: X3 26: Torque limit detection 68: PD8
16: Position preset 54: Free-run [BX] 27: Overload early warning 69: PD9
27: Pulse train ratio 1 55: Edit permit command 28: CPU ready 70: PD10
28: Pulse train ratio 2 29: Edit permit ON/OFF 71: PD11
29: P-action 30: Data error 72: PD12
30: Torque limit 31: Address error 73: PD13
31: Temporary stop 32: Alarm code 0 74: PD14
32: Positioning cancel 33: Alarm code 1 75: Position preset end
T-link
(T-link direct