EasyManua.ls Logo

Fuji Electric FRENIC MEGA G2 Series - Page 214

Fuji Electric FRENIC MEGA G2 Series
970 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Function Code Tables
5-30
Function
code
Name
Control method and Data setting range
Change when running
Data copying
Factory
default
Related page
b43
Speed control 3
(Speed command filter)
Same as A43
Y
Y
0.020
5-296
b44
(Speed detection filter)
Same as A44
Y*
Y
0.005
b45
(P gain)
Same as A45
Y*
Y
10.0
b46
(I integral time)
Same as A46
Y*
Y
0.100
b47
FF (Gain)
Same as A47
Y*
Y
0.00
b48
(Output filter)
Same as A48
Y
Y
0.002
b49
(Notch filter resonance
frequency)
Same as A49
Y
Y
200
b50
(Notch filter attenuation
level)
Same as A50
Y
Y
0
b51
Cumulative run time of
motor 3
Same as A51
N
N
0
b52
Startup count for motor 3
Same as A52
Y
N
0
b53
Motor 3
(%X correction factor 1)
Same as A53
Y
Y1Y2
100
b54
(%X correction factor 2)
Same as A54
Y
Y1Y2
100
b55
(Torque current under
vector control)
Same as A55
N
Y1Y2
*6
b56
(Induced voltage factor
under vector control)
Same as A56
N
Y1Y2
*6
b57
(For adjustment by
manufacturer *9)
Same as A57
Y
Y1Y2
*6
b58
Speed control 3
(Notch filter width)
Same as A58
Y
Y
2
b60
Speed display coefficient 3
Same as A60
Y
Y
0.00
b61
Constant rate of feeding
coefficient 3/
Speed display auxiliary
coefficient 3
Same as A61
Y
Y
1.000
b62
Starting frequency 3
(Holding time)
Same as A62
Y
Y
0.00
b63
Stop frequency 3
Same as A63
Y
Y
999
b64
(Detection method)
Same as A64
N
Y
100
b65
(Holding time)
Same as A65
Y
Y
0.00
b66
Motor 3
(Thermistor operation
selection)
Same as A66
Y
Y
100
b67
(Operation level)
Same as A67
Y
Y
0.35
b98
(Function selection)
Same as A98
N
Y
0
5-265
*9: This is a function code for adjustment by the manufacturer. Do not access these function codes.
*10: 5.0 min for FRN0115G2S-2G/FRN0060G2-4G or lower inverters, 10.0 min for FRN0146G2S-2G/FRN0075G2-4G or higher inverters

Table of Contents

Related product manuals