12.2 Standard Specifications 2 (Type with Built-in EMC Filter)
12-8
12.2 Standard Specifications 2 (Type with Built-in EMC Filter)
12.2.1 Three-phase 400V series
HHD specification for High, Heavy Duty applications
Item
Specification
Type (FRN***G2E-4G)
0002
0003
0004
0006
0009
0018
0023
0031
0038
0045
0060
0075
0091
0112
0150
Standard applicable motor
[kW (HP)] (*1)
(rated output)
0.4
(1/2)
0.75
(1)
1.5
(2)
2.2
(3)
3.7
(5)
5.5
(7.5)
7.5
(10)
11
(15)
15
(20)
18.5
(25)
22
(30)
30
(40)
37
(50)
45
(60)
55
(75)
Output ratings
Rated capacity [kVA]
(*2)
1.1
1.9
3.2
4.5
6.8
10
14
18
24
29
34
45
57
69
85
Rated voltage [V] (*3)
Three-phase 380 to 480 V (with AVR function)
Rated current [A]
1.5
2.5
4.2
6.0
9.0
13.5
18.5
24.5
32
39
45
60
75
91
112
Overload current rating
150% for 1 min, 200% for 3.0 s
Input power supply
Voltage, frequency
Three-phase 380 to 480 V, 50/60 Hz
Permissible voltage,
frequency fluctuation
Voltage: +10 to -15% (interphase unbalance ratio: 2% or less) (*4)
Frequency: +5 to -5%
Rated input
current [A]
(*8)
with
DCR
0.85
1.6
3.0
4.5
7.5
10.6
14.4
21.1
28.8
35.5
42.2
57.0
68.5
83.2
102
w/o
DCR
1.7
3.1
5.9
8.2
13
17.3
23.2
33
43.8
52.3
60.6
77.9
94.3
114
140
Required capacity
(with DCR) [kVA] (*5)
0.6
1.2
2.1
3.2
5.2
7.4
10
15
20
25
30
40
48
58
71
Braking
Braking torque [%] (*6)
150%
100%
20%
10 to 15%
Braking transistor
Built-in
Minimum connectable
resistance value [Ω]
200
160
96
64
48
32
24
16
10
9.0
8.0
6.5
Built-in braking resistor
[Ω]
720
470
160
80
-
Braking time [s]
5 s
-
Duty cycle [%ED]
5
3
5
3
2
3
2
-
EMC filter
Complying EMC standard on emissions and immunity: Category C3 (2nd Env.)
(IEC61800-3)
DC reactor (DCR)
Option
Applicable safety standards
UL61800-5-1, C22.2 No.274-17, IEC/EN 61800-5-1
Protective construction (IEC
60529)
Enclosed IP20 type, UL open type
IP00, UL open type
IP55 at external side
when external cooling
installed
Cooling system
Natural cooling
Fan cooling
Weight [kg (lbs)]
1.8
(3.9)
2.1
(4.5)
2.8
(6.1)
3.1
(6.8)
3.2
(6.9)
6.6
(15)
6.6
(15)
6.4
(14)
11
(25)
11
(25)
12
(25)
23
(51)
23
(51)
30
(66)
31
(68)
(*1) Fuji 4-pole standard motor
(*2) The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
(*3) It is not possible to output a voltage higher than the power supply voltage.
(*4) Interphase unbalance ratio (%) = Max. voltage [V] - min. voltage [V] / Three-phase average voltage [V] x 67
(See IEC/EN 61800-3)
If using the motor with an unbalance ratio of 2 to 3%, use an AC reactor (ACR: option).
(*5) This indicates the capacity when the motor is equipped with a DC reactor (DCR).