8.7 Control Section
8-13
BLOCK DIAGRAMS FOR CONTROL LOGIC
Chap 8
[ 2 ] Torque command / torque limit
Torque limit value 1-2 (braking)
Torque limit value 1-1 (drive)
Torque limit value 2-2 (braking)
Torque limit value 2-1 (drive)
Torque limit (operating requirement selection)
Torque limit (control target)
Torque limit (applicable
quadrant)
H30
y99
y98
H30
y99
y98
Analog torque
command
Multifunctional
Keypad
0,2,6
1,35,7,8
0,2
1,3
0,2
1,3
0,2,6
1,35,7,8
0,2
1,3
0,2
1,3
Select link
operation
LE
Multifunctional
Keypad
Select local
(Keypad)
command
"LOC"
Remote/local
decision
S02
S03
Analog torque limit value B
F40
E16
S10
7
7
8
8
Communication
torque limiting
F41
E17
S11
Communication
torque limiting
+300% (Driving)
-300% (Braking)
Terminal [12], [C1], [V2], [V3]
(Extended function)
Analog torque limit value A
Torque limit
value
calculator
H75
Torque Limiter (Driving)
Torque Limiter (Braking)
o60
o76
Terminal [32], [C2]
(Extension function selection of option AIO card)
Terminal [32], [C2]
(Extension function selection of option AIO card)
o60
o76
Select torque bias 1
Torque-bias (Level 1)
Torque-bias (Level 2)
Torque-bias (Level 3)
H158
Torque bias
(Mechanical loss
compensation)
Run command direction
(FWD/REV)
H159
H161
Select torque bias 2
"TB1"
"TB2"
H162
Torque bias value
-1
Holding torque
bias processing
+
+
H155
H156
H157
Selector
H154
Torque bias
(Mode selection)
Analog torque bias value
0 %
0 %
Operation
command ON
Torque bias
(Limiter)
0
2
1
H69
Anti-regenerative control
(Mode selection)
E61 E62 E63
E61 E62 E63
Link function
Bus
function
Host
equipment
Host
equipment
Host
equipment
*2
Field bus card
(option)
LED display
88888
S15
H162
+
+
E66
Terminal [12], [C1], [V2], [V3]
(Extended function)
E66
H154
Torque bias
(Mode selection)
0,1,2
3,4,5
H74
H73
RS-485 communication port 1
Connector for connecting keypad
RS-485 communication port 2
Control circuit terminals DX+, DX-
Select torque
limit 2/1
"TL2/TL1"
*2: Refer to the respective instruction manuals for details on each option.
Torque bias command
Torque bias
(Limiter)
Torque bias (Shutdown timer)
Torque bias (Startup timer)
Hold torque bias
"H-TB"
Priority to later
writing
Select local
(Keypad)
command
"LOC"
Select link operation
LE
Remote/local
decision
Link function
Bus function
Analog torque
command
Set torque
command via
communication
Fig. 8.7-5 Vector control (torque command / torque limit) section block diagram