5.3 Description of Function Codes 5.3.1 F codes (Fundamental functions)
<If decelerating from a fixed output area>
The fixed output area (base frequency or higher) braking load is constant. Furthermore, the fixed torque area (less
than base frequency) braking load is proportional to the speed. Consequently, if decelerating (stopping) from the
fixed output area, calculate and add the discharge withstand current rating and permissible average loss for the
respective <If expressed with %ED for constant speed> and <If decelerating from a fixed output area> above.
Discharging capability (F50)
The discharging capability refers to kWs allowance for a single braking cycle.
Disables the protective function with a braking resistor electronic thermal
overload.
Allowable average loss (F51)
Allowance average loss is the resistor capacitor that enables continuous operation of motor.
Braking resistance value (F52)
F52 specifies the resistance of the braking resistor.
Terminal [FM1] (Filter, Bias)
Terminal [FM2] (Operation selection, Output gain, Function selection, Filter,
Bias)
A detailed explanation can be found in the function code F29 section.
A detailed explanation can be found in the function code F33 section.