5.3 Description of Function Codes 5.3.2 E codes (Extension terminal functions)
5-160
By setting the same data as that shown in the following table for function code E71, terminal functions indicated
with a “Y” in the “Applicable to M-LED” column can monitor signals with the keypad M-LED. Refer to the explanation
on function code E71 for details.
LED
Defined function
Signal name
Applica
ble to
M-LED
Related
function
codes/related
signals (data)
Active ON
Active OFF
0
1000
Change
"RUN"
Y
-
1
1001
Frequency (speed) arrival
"FAR"
Y
E30
2
1002
Frequency (speed) detected
“FDT”
Y
E31, E32
3
1003
Undervoltage detected (Inverter stopped)
"LU”
Y
-
4
1004
Detected torque polarity
“B/D”
Y
-
5
1005
Inverter output limiting
"IOL"
Y
-
6
1006
Auto-restarting after momentary power failure
"IPF"
Y
F14
7
1007
Motor overload early warning
"OL"
Y
E34, F10, F12
8
1008
Keypad operation
"KP"
Y
-
10
1010
Inverter ready to run
"RDY"
Y
-
11
-
Commercial/inverter operation switching
(commercial power supply side magnetic
contactor)
“SW88”
N
12
-
Commercial/inverter operation switching
(inverter output side)
“SW52-2”
N
13
-
Commercial/inverter operation switching
(inverter input side)
“SW52-1”
N
15
1015
AX terminal function (for input side magnetic
contactor)
"AX"
N
-
16
1016
Pattern operation stage transition
"TU"
Y
17
1017
Pattern operation cycle completed
"TO"
Y
18
1018
Pattern operation stage No. 1
“STG1”
Y
19
1019
Pattern operation stage No. 2
“STG2”
Y
20
1020
Pattern operation stage No. 4
“STG4”
Y
21
1021
Frequency (speed) arrival 2
“FAR2”
Y
E29
22
1022
Inverter output limiting (with delay)
“IOL2”
Y
IOL (5)
25
1025
Cooling fan ON-OFF control
"FAN"
Y
H06
26
1026
Auto-resetting
"TRY"
Y
H04, H05
27
1027
Universal DO
“U-DO”
Y
-
28
1028
Cooling fin overheat early warning
"OH"
Y
-
29
1029
Synchronization completed
"SY"
Y
d17 to d78
30
1030
Lifetime alarm
"LIFE"
Y
H42
31
1031
Frequency (speed) detection 2
“FDT2”
Y
E32, E36
33
1033
Reference loss detected
“REF OFF”
Y
E65
35
1035
Inverter outputting
“RUN2”
Y
“RUN” (0)
36
1036
Overload prevention controlling
"OLP"
Y
H70
37
1037
Current detected
"ID"
Y
E34, E35
38
1038
Current detected 2
“ID2”
Y
E37, E38
39
1039
Current detected 3
“ID3”
Y
E55, E56