5.3 Description of Function Codes 5.3.9 d codes (Applied functions 2)
Constant surface speed control (Selector switch)
Related function codes:
d41 (Application control selection)
J01 PID control (Operation selection)
By using winding diameter calculation, constant surface (line speed) speed control can be performed even if the
roll winding diameter ratio changes significantly. If using winding diameter calculation, set d154 to 1.
• Data setting range: 0 to 1
Bit 0:
Winding diameter
compensation
0: Disable
(factory
default)
Disables winding diameter calculation, and runs the
inverter at the frequency setting from the host controller.
The frequency setting for which winding diameter
compensation was performed at the host controller is
used.
Enables winding diameter calculation, and runs the
inverter with the frequency command for which
compensation was performed with the winding diameter
calculated by the inverter. The line speed setting is used
for the inverter.
Winding diameter calculation
Related function codes: d41 (Application control selection)
J01 PID control (Operation selection)
Calculates the roll winding diameter for constant surface speed control from the peripheral speed (line speed)
setting and roll rotation speed, compensates the output frequency even if the roll winding diameter changes, and
controls the speed so that the peripheral speed (line speed) remains constant when winding and unwinding.
Winding diameter calculation is valid only when PID control for dancer control is enabled (J01 = 3).
ロール部検出速度
(換算値)
×
巻径演算(補正ゲイン)
d161
ライン速度設定
巻径演算(演算ゲイン) d160
d158
d159
d164
d163
最大巻径
最小巻径
LED表示
E43=27の時
0~65535 ㎜で表示
E43
巻径演算(不感帯)
巻径演算(移動平均回数)
×
-1
<FWD>
<REV>
REV
FWD
0
STOP
巻径演算
d165
初期巻径
X端子[D-SET] ONで設定
X端子[D-HLD]
ONでホールド
ホールド
初期径セット
÷ 巻径比
×
巻径演算(FM出力ゲイン)
d166
d162 巻径演算(最低ライン速度比率)
アナログ出力
端子【FM1】【FM2】
0~10 V
Winding diameter calculation (Calculation gain)
Winding diameter calculation (Dead zone)
Winding diameter calculation (Moving average count)
Winding diameter calculation (Low-speed line speed ratio)
Winding diameter calculation (Compensation gain)
Winding diameter calculation
Roll detection speed
(Conversion value)
Analog output
terminal [FM1], [FM2]
0 to 10 V
Winding diameter calculation (FM output gain)
When E43 = 27
Indicates 0 to 65535 ㎜