6.3 If an Alarm Code Appears on the LED Monitor
6-7
Table 6.3-1 cont.
Warning selection
possible
For investigation by manufacturer
Charger circuit error
(FRN0008G2S-2G/
FRN0004G2■-4G or above)
For investigation by manufacturer
For investigation by manufacturer
Excessive positioning deviation
Note) • All protective functions are automatically reset if the control power voltage drops to a level at which
inverter control circuit operation can no longer be sustained.
• The protection stop condition can be canceled by pressing the keypad key, or turning between the X
(assigned to RST) and CM terminals OFF to ON. However, the reset operation will not be valid until the
cause of the alarm has been eliminated.
• If multiple alarms have occurred, the reset operation will not be valid until the cause of all alarms has been
eliminated. (The cause of uncleared alarms can be checked at the keypad.)
• When assigned to warnings, terminals [30A/B/C] do not work.