11.8 Braking Resistors (DB) and Braking Units
11-21
SELECTING PERIPHERAL EQUIPMENT
Chap 11
Table 11.8-4 Braking resistors (10%ED type) for HHD specification
Power
system
Standard
applicable
motor (kW)
[HP]
Inverter type
Option
Maximum braking torque (%)
Continuous braking
(100% braking torque)
Repetitive braking
(each cycle is 100 s or less)
Breaking resistors
HHD specification
Type
Qty
Resistance
(Ω)
50 Hz
60 Hz
Discharge
withstand
current rating
(kWs)
Braking time
(s)
Average
allowable loss
(kW)
Duty cycle
(%ED)
(N·m)
(N·m)
Three-phase 200 V
0.4 [1/2]
FRN0003G2S-2G
DB0.75-2C
1
100
150
4.02
3.32
50
250
0.075
37
0.75 [1]
FRN0005G2S-2G
7.57
6.25
50
133
0.075
20
1.5 [2]
FRN0008G2S-2G
DB2.2-2C
1
40
15
12.4
55
73
0.110
14
2.2 [3]
FRN0011G2S-2G
22
18.2
55
50
0.110
10
3.7 [5]
FRN0018G2S-2G
DB3.7-2C
1
33
37.1
30.5
140
75
0.185
5.5 [7.5]
FRN0032G2S-2G
DB5.5-2C
1
20
54.3
45
55
20
0.275
7.5 [10]
FRN0046G2S-2G
DB7.5-2C
1
15
73.6
61.6
37
10
0.375
11 [15]
FRN0059G2S-2G
DB11-2C
1
10
108
89.5
55
10
0.55
15 [20]
FRN0075G2S-2G
DB15-2C
1
8.6
147
122
75
10
0.75
18.5 [25]
FRN0088G2S-2G
DB22-2C
1
5.8
182
151
92
10
0.925
22 [30]
FRN0115G2S-2G
216
179
110
10
1.1
Three-phase 400 V
0.4 [1/2]
FRN0002G2-4G
DB0.75-4C
1
200
150
4.02
3.32
50
250
0.075
37
0.75 [1]
FRN0003G2-4G
7.57
6.25
50
133
0.075
20
1.5 [2]
FRN0004G2-4G
DB2.2-4C
1
160
15
12.4
55
73
0.110
14
2.2 [3]
FRN0006G2-4G
22
18.2
55
50
0.110
10
3.7 [5]
FRN0009G2-4G
DB3.7-4C
1
130
37.1
30.5
140
75
0.185
5.5 [7.5]
FRN0018G2-4G
DB5.5-4C
1
80
54.3
45
55
20
0.275
7.5 [10]
FRN0023G2-4G
DB7.5-4C
1
60
73.6
61.6
37
10
0.375
11 [15]
FRN0031G2-4G
DB11-4C
1
40
108
89.5
55
10
0.55
15 [20]
FRN0038G2-4G
DB15-4C
1
34.4
147
122
75
10
0.75
18.5 [25]
FRN0045G2-4G
DB22-4C
1
22
182
151
92
10
0.925
22 [30]
FRN0060G2-4G
216
179
110
10
1.1
The 10%ED type is not equipped with a function for outputting temperature detection signals, and
therefore it is necessary to specify electronic thermal overload relay function (function code F50, F51,
F52) settings for braking resistor protection.
(Note) □ in the inverter type is replaced by a letter of the alphabet.
S (basic type), E (type with built-in EMC filter)
Table 11.8-5 Braking resistors (10%ED type) for HND specification
Power
system
Standard
applicable
motor (kW)
[HP]
Inverter type
Option
Maximum braking torque (%)
Continuous braking
(100% braking torque)
Repetitive braking
(each cycle is 100 s or less)
Breaking resistors
HND specification
Type
Qty
Resistance
(Ω)
50 Hz
60 Hz
Discharge
withstand
current rating
(kWs)
Braking
time (s)
Average
allowable loss
(kW)
Duty cycle
(%ED)
(N·m)
(N·m)
Three-phase
200 V
7.5 [10]
FRN0032G2S-2G
DB5.5-2C
1
20
100
49.6
41
55
15
0.275
10
11 [15]
FRN0046G2S-2G
DB7.5-2C
1
15
72
59.7
37
7
0.375
10
15 [20]
FRN0059G2S-2G
DB11-2C
1
10
98.1
81.4
55
7
0.55
10
18.5 [25]
FRN0075G2S-2G
DB15-2C
1
8.6
121
100
75
7
0.75
7
22 [30]
FRN0088G2S-2G
DB22-2C
1
5.8
144
119
93
7
0.925
7
30 [40]
FRN0115G2S-2G
195
162
110
7
1.1
7
Three-phase
400 V
7.5 [10]
FRN0018G2-4G
DB5.5-4C
1
80
100
49.6
41
55
15
0.275
10
11 [15]
FRN0023G2-4G
DB7.5-4C
1
60
72
59.7
38
7
0.375
10
15 [20]
FRN0031G2-4G
DB11-4C
1
40
98.1
81.4
55
7
0.55
10
18.5 [25]
FRN0038G2-4G
DB15-4C
1
34.4
121
100
75
7
0.75
7
22 [30]
FRN0045G2-4G
DB22-4C
1
22
144
119
93
7
0.925
7
30 [40]
FRN0060G2-4G
195
162
110
7
1.1
7
The 10%ED type is not equipped with a function for outputting temperature detection signals, and
therefore it is necessary to specify electronic thermal overload relay function (function code F50, F51,
F52) settings for braking resistor protection.
(Note) □ in the inverter type is replaced by a letter of the alphabet.
S (basic type), E (type with built-in EMC filter)

Table of Contents

Related product manuals