12.3 Common Specifications
When
performing
sensorless
vector control
∙ 1:200
(Minimum speed: Nominal speed, 4P, 7.5 to 1500 r/min)
∙ 1:2 (fixed torque area : fixed output area)
∙ Analog setting: ±0.5% of nominal speed or below
(at 25 ±10 °C) (77 ±18 °F)
∙ Digital setting: ±0.5% of nominal speed or below
(at -10 to +50 °C) (14 to 122 °F)
When
performing
vector control
with sensor
∙ 1:1500
(Minimum speed: Nominal speed, 4P, 1 to 1500 r/min)
∙ 1:16 (fixed torque area : fixed output area)
∙ Analog setting: ±0.2% of maximum output frequency or
below (at 25 ±10 °C) (77 ±18 °F)
∙ Digital setting: ±0.01% of maximum output frequency or
below (at -10 to +50 °C) (14 to 122 °F)
When
performing
sensorless
vector control
∙ 1:10
(Minimum speed: Nominal speed, 6P, 180 to 1800 r/min)
∙ 1:2 (fixed torque area : fixed output area)
∙ Analog setting: ±0.5% of nominal speed or below
(at 25 ±10 °C) (77 ±18 °F)
∙ Digital setting: ±0.5% of nominal speed or below
(at -10 to +50 °C) (14 to 122 °F)
When
performing
vector control
with sensor
∙ 1:1500
(Minimum speed: Nominal speed, 4P, 1 to 1500 r/min)
∙ 1:2 (fixed torque area : fixed output area)
∙ Analog setting: ±0.2% of maximum output frequency
(at 25 ±10 °C) (77 ±18 °F)
∙ Digital setting: ±0.01% of maximum output frequency
(at -10 to +50 °C) (14 to 122 °F)
∙ V/f control
∙ Dynamic torque vector control
∙ V/f control with sensor,
dynamic torque vector control with sensor
∙ Sensorless vector control
∙ Vector control with sensor
∙ Sensorless vector control (synchronous motors)
∙ Vector control with sensor (synchronous motors)
Voltage/frequency
characteristics
∙ The base frequency and maximum output frequency are
common, and the voltage can be set between 80 and 240 V.
∙ AVR control can be turned ON or OFF.
∙ Non-linear V/f setting (3 points): The desired voltage (0 to 240
V) and frequency (0 to 599 Hz) can be set.
∙ The base frequency and maximum output frequency are
common, and the voltage can be set between 160 and 500 V.
∙ AVR control can be turned ON or OFF.
∙ Non-linear V/f setting (3 points): The desired voltage (0 to 500
V) and frequency (0 to 599 Hz) can be set.