EasyManuals Logo

Fuji Electric Time Delta-C FSV-2 User Manual

Fuji Electric Time Delta-C FSV-2
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
-102-
7.3. ORDERING INFORMATION
1. Type of detector
2. Type of flow transmitter
3. Type of signal cable
4. Tag No. (When tag plate is specified)
5. Parameter setting list (When parameter setting is specified)
Company name
:
Branch:
Name of the contact person: TEL:
Measuring fluid:
Parameter setting list
Setting items Initial value Setting value Setting items Initial value Setting value
ID No 0000
Output condition
Total output
Total mode Stop
Language English Pulse value 0m
3
Measurement condition
System unit Metric Total preset 0m
3
Flow unit m
3
/h Pulse width 50.0msec
Total unit m
3
Burnout (total) Hold
Outer diameter 60.00mm Burnout timer 10sec
Pipe material PVC DO1 Output type (Note1) Not used
Wall thickness 4.00mm DO1 Output operation Active ON
Lining material No lining DO2 Output type Not used
Lining thickness - DO2 Output operation Active ON
Kind of fluid Water Operation mode Standard
Viscosity 1.0038×10
-6
m
2
/s
Communica
tion
Communication mode RS-485
Sensor mount V method Baud rate 9600bps
Sensor type FSSA Parity Odd
Output condition
Damping 5.0sec Stop bit 1 bit
Cut off 0.150m
3
/h Station No. 1
Display
Content of 1st line Velocity (m/s)
Decimal point
position of 1st line

.

Content of 2nd line Flow Rate (m
3
/h)
Decimal point
position of 2nd line

.

Analog output
KIND FLOW RATE
Range type SINGLE
Full scale 1 15.000m
3
/h
Full scale 2 0.000m
3
/h
Hysteresis 10.00%
Burnout (current) HOLD
Burnout timer 10sec
Output limit low -20%
Output limit high 120%
Rate limit 0.000m
3
/h
Rate limit timer 0sec
Note 1) When total pulse output has been selected for DO1 and/or DO2 specify total pulse value and total pulse width so that conditions 1
and 2 shown below are satisfies.
Condition 1:
Full scale*1 [m
3
/s]
Pulse value [m
3
]
100[Hz]
Condition 2:
Full scale*1 [m
3
/s]
Pulse value [m
3
]
1000
2 × Pulse width [ms]
*1) The range of FULL SCALE 1 or FULL SCALE 2, whichever is larger, is the object in case of automatic 2-range, forward and
reverse range, forward and reverse automatic 2-range.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric Time Delta-C FSV-2 and is the answer not in the manual?

Fuji Electric Time Delta-C FSV-2 Specifications

General IconGeneral
BrandFuji Electric
ModelTime Delta-C FSV-2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals