-30-
4.8. Setting of unit
4.8.1. How to set the unit system
Description
Measurement unit can be selected from metric or inch system.
Metric system (factory set)
Length ······································ mm
Flow velocity ······························ m/s
Flow rate ·································· L/s, L/min, L/h, L/d, kL/d, ML/d, m
3
/s, m
3
/min, m
3
/h, m
3
/d, km
3
/d, Mm
3
/d, BBL/s, BBL/min, BBL/h,
BBL/d, kBBL/d, MBBL/d
Total unit ··································· mL, L, m
3
, km
3
, Mm
3
, mBBL, BBL, kBBL
Kinematic viscosity coefficient ······· E
-6
m
2
/s
<Note> When setting, stop status should be set at total mode. (See Section 4.9.2.)
For actual keying, refer to the typical operation indicated below. Set the protection to OFF beforehand. (See Section 4.4.1.)
Operation
(example)
Change the unit system from inch system to metric system.
Key operation Description Display
▼
Press the key for 3 times to display “MEASURE SETUP”.
MEASURE SETUP
ENT
▼
Press the
ENT
key once to display “SYSTEM UNIT”.
SYSTEM UNIT
INCH
ENT
▼
Press the
ENT
key once to blink the cursor.
SYSTEM UNIT
INCH
▼
Press the key once to display “METRIC”.
SYSTEM UNIT
METRIC
ENT
▼
▼
▼
▼
Press the
ENT
key once to register.
SYSTEM UNIT
COMPLETE
↓
――― METRIC has been registered. ―――
SYSTEM UNIT
METRIC
ESC
Press the
ESC
key once and key twice to return to the measurement
mode.
0.000 m/s
0.000 m3/h