CHAPTER 3
Small Configuration
Installing the 19-Inch (SFD5) DCM Shelf
3-59
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
4 Identify the left and right shelf flanges. See Figure 3-41 [p. 3-57] and Figure 3-43 [p. 3-59].
Note: At first glance the two flanges for 19-inch rack mounting appear to be identical, but they are
not. As shown in Figure 3-43 [p. 3-59], the top two clearance holes are slightly farther apart than the
bottom two clearance holes.
5 Identify the flange mounting holes for 19-Inch rack installation on the side of the SFD5 shelf.
See Figure 3-44 [p. 3-59].
Figure 3-43: SFD5 Shelf Mounting Flanges (Front View)
Figure 3-44: Flange Mounting Holes on Right Side of SFD5 Shelf (19-Inch Rack Installation)
Larger Space
(Top)
Smaller Space
(Bottom)
Left Shelf Flange Right Shelf Flange
L R
m1656sm_3
Mounting Holes