CHAPTER 4
ETSI Configuration
Installing the ETSI DCM (SFD6) Shelf
4-33
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
3 Identify the left and right shelf flanges. See Figure 4-15 [p. 4-32] and Figure 4-16 [p. 4-33].
Note: At first glance the two flanges for ETSI rack mounting may appear to be identical, but they are
not. As shown in Figure 4-16 [p. 4-33], the space between the upper edges and the top clearance
holes is slightly larger (3 mm) than the space between the lower edges and the bottom clearance
holes.
Figure 4-16: SFD6 Shelf Mounting Flanges (Front View)
Left Shelf Flange Right Shelf Flange
L R
m1718pz_1
Revision 1, June 2009