CHAPTER 4
ETSI Configuration
Installing Fans, Rack Covers, and End Panels
4-45
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
3 In the mounting holes vacated in Step 2 [p. 4-44], install two of each type of standoff as
shown in Figure 4-27 [p. 4-45]. Ensure that the external tooth lockwasher is installed on the
standoffs before tightening.
Note: The standoffs with the “hook” ends are installed in the two upper locations. The standoffs with
the threaded holes are installed in the lower locations.
Figure 4-27: Lower Cover Mounting Screws and Standoff Locations
r1419_1
Replace mounting screws in top
two indicated locations with:
2 PC210-0001-X028 standoffs, pin/hook
2 D4-WTE250-33 external tooth washers
Replace mounting screws in bottom
two indicated locations with:
2 PC210-0001-X027 standoffs, pin/socket
2 D4-WTE250-33 external tooth washers