CHAPTER 6
Installing/Removing Modules, Filler Panels and Plug-In Units
Installing/Removing SFP Modules in a Muxponder or Flexponder™ Unit
6-15
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
5 Locate the module to be removed, and inspect the fiber connections (if any). See Figure 6-9
[p. 6-15]. Verify that each fiber is clearly marked or labeled to identify the connector to which
it connects.
Note: Fiber marking or labeling depends on local practice.
6 Is each fiber clearly marked to show the connector to which it connects?
If YES:
Continue to Step 7 [p. 6-15].
If NO:
Mark or label fibers according to local practice. Then repeat this step.
7 Disconnect the fiber-optic cables from the module to be removed.
Figure 6-9: Fiber Connections to SFP Module Installed in IFMA-GUC1 Unit