EasyManuals Logo

Fujitsu SPARC EnterpriseM3000 User Manual

Fujitsu SPARC EnterpriseM3000
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #288 background imageLoading...
Page #288 background image
Chapter 4 Operation of the Server 4-27
4.7 Changing the Time
The time of the server is based on the XSCF time. Time can be displayed or set to
local time or UTC. For details on displaying or setting the system time, see
Chapter 2.
4.8 Switching the XSCF Unit
In some cases, such as when an error occurs in the LAN route of the XSCF Unit on
the active side in a system in which the XSCF Unit is redundantly configured, it may
be necessary to switch the active side over to the standby side.
The procedure for switching the XSCF Unit status from standby to active is as
follows:
â–  Command operation
1. Log in the XSCF Unit on the standby side.
2. Use the switchscf(8) command to switch the XSCF Unit from standby status
to active status.
Note – If possible, confirm that the ACTIVE LED states changes on the front panels
of both XSCF Units. Execute the switchscf(8) command only on one side (active
side or standby side) of the XSCF Units to automatically switch active/standby
status of the other XSCF Unit.
For specifying an option in the switchscf(8) command, see the XSCF Reference
Manual.
Processing Continued at XSCF Reset or Failover
In case an XSCF reset or failover was generated while the following processes are
executing, the process will be continued:
â–  Domain power-on process
â–  Domain power-off process
â–  DR function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC EnterpriseM3000 and is the answer not in the manual?

Fujitsu SPARC EnterpriseM3000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC EnterpriseM3000
CategoryServer
LanguageEnglish

Related product manuals