Chapter 4 Operation of the Server 4-33
Displaying and Clearing the Card with ESM
■ Command operation
● Use the ioxadm(8) command to display and clear runtime of the card with
ESM.
4.10 Restore Factory Settings of the Server or
XSCF Unit
To restore the server or the XSCF Unit to the factory settings, execute the
restoredefaults(8) command on the XSCF Unit.
Caution – IMPORTANT - User information and error logs are cleared from the
XSCF Unit.
The restoredefaults(8) command can initialize the server (Operator panel and the
XSCF Unit) or the XSCF Unit.
When the command is executed on the active XSCF of the M8000/M9000 server,
both the active and standby XSCF or the server (the operator panel and both XSCF
Units) are initialized. However, when the command is executed on the standby XSCF
of the M8000/M9000 server, only the standby XSCF is initialized. The server or the
active XSCF cannot be initialized from the standby XSCF.
■ Command operation
To execute this command:
1. Connect to the XSCF over a serial connection.
<Example 1> Display runtime of card with ESM using verbose output.
XSCF> ioxadm -v lifetime IOU#0-PCI#1
NAC Total Time On (% of life) Warning Time Fault Time
IOU#0-PCI#1 1052370 100 1041120 1051200
<Example 2> Clear runtime of card with ESM, show runtime is cleared.
XSCF> ioxadm lifetime -z IOU#0-PCI#1
XSCF> ioxadm lifetime IOU#0-PCI#1
NAC Total Time On (% of life)
IOU#0-PCI#1 0 0