Chapter 2 Setting Up XSCF 2-181
Note – The display for domain ethernet address (mac address) by the
showdomainmode(8) command is supported only on
M3000/M4000/M5000/M8000/M9000 servers that run certain versions of XCP
firmware (beginning with XCP 1082).
The Status of the Mode Switch on Oracle Solaris OS
When you execute the prtdiag(1M) command on Oracle Solaris OS, either "LOCK"
or "UNLOCK" is displayed in the output as the status of the mode switch of the
operator panel. The output varies depending on the combination of the value of the
secure variable, which is set on each domain by using the setdomainmode(8)
command and the key position of the mode switch on the operator panel.
TABLE 2-33 shows the status of the mode switch displayed in the prtdiag (1M)
command output which depends on the value of secure variable and the key
position of the mode switch on the operator panel.
For details of the setdomainmode(8) command, see the XSCF Reference Manual.
For details of the prtdiag(1M) command, see the Oracle Solaris OS documentation.
SPARC64 VII+, SPARC64 VII, and SPARC64 VI Processors and CPU
Operational Modes
The M4000/M5000/M8000/M9000 support system boards that contain SPARC64
VII+, SPARC64 VII, and SPARC64 VI processors, or a mix of these processor types.
The M3000 servers support only SPARC64 VII+ or SPARC64 VII processors.
This section applies only to M4000/M5000/M8000/M9000 servers that run or will
run SPARC64 VII+ or SPARC64 VII processors. On the M3000 server, only SPARC64
VII+ or SPARC64 VII processor is mounted and Oracle Solaris OS operates in
SPARC64 VII enhanced mode.
TABLE 2-33 Value of Secure Variable and Status of Mode Switch
Value of secure
variable set by
setdomainmode(8) Key position of mode switch
Status of mode switch in the
prtdig(1M) output
on Service UNLOCK
off UNLOCK
on Locked LOCK
off UNLOCK

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC EnterpriseM3000 and is the answer not in the manual?

Fujitsu SPARC EnterpriseM3000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC EnterpriseM3000
CategoryServer
LanguageEnglish

Related product manuals