A-2 SPARC Enterprise Mx000 Servers XSCF User’s Guide • January 2012
â–  Panic message
This message is output in case of panic. The panic message is output to the domain
console and retained as log information in the XSCF. The panic log retains the
information corresponding to the last single panic event that occurred. The
showlogs(8) command of XSCF can be used to display the panic log.
â–  Console message
The console message is a general term used to describe syslog messages, FMA
messages, panic messages, IPL messages, and other messages output by POST,
OpenBoot PROM, and the Oracle Solaris OS. The console messages are output to
each domain console and are retained as log information (in a console log) in the
XSCF. The showlogs(8) command of the XSCF Shell can be used to display the
console log.
Note – Console messages are overwritten, beginning with the oldest message. Even
when the wraparound feature causes a console message to be overwritten, the
system startup message is retained in the IPL log, and in case of panic, the log is
retained in the panic log.
When the XSCF unit is redundant, the console messages retained in the XSCF Unit
on the active side are not copied to the standby side. Accordingly, after the XSCF
Unit is switched, the console messages on the previously active side cannot be
referenced.
â–  Monitoring message
The XSCF firmware outputs this message to notify the server fault or status. The
monitoring message is output by using the showmonitorlog(8) command, and
retained as log information (in a monitor message log or XSCF error log) in the
XSCF. The showlogs(8) command of the XSCF Shell can be used to display the
monitoring message and XSCF error log for more detailed investigation. Authorized
service personnel use the DIAGCODE output in the message to acquire detailed
information.
Note – Monitoring messages are overwritten, beginning with the oldest message.
When the XSCF Unit is redundant, monitoring messages output by the XSCF Unit on
the active side are also managed on the standby side. Even after the XSCF Unit is
switched, the monitoring messages on the previously active side can be referenced.
â–  Other notice message
In addition to the messages above, there is a notification message displayed on the
domain console when power off or reset processing is performed normally or an
event occurs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC EnterpriseM3000 and is the answer not in the manual?

Fujitsu SPARC EnterpriseM3000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC EnterpriseM3000
CategoryServer
LanguageEnglish

Related product manuals