6. DISTRESS OPERATIONS
6-3
16.Press the [Esc] key to show the update window.
Setup
Distress Alert Setup
LES ID
Update Time
Position
Protocol
Nature
Course
Speed
303 (KDDI)
06:23 02-02-25 (YY-MM-DD)
LAT 30:00N
LON 140:00E
Maritime
Grounding
187
0 KTS
Update
No
Yes
Distress alert setup, update window
17. Yes is selected; press the [Enter] key to register settings.
Setup
Distress Alert Setup
LES ID
Update Time
Position
Protocol
Nature
Course
Speed
Distress Alert updated.
Press any key to escape.
303 (KDDI)
06:23 02-02-25 (YY-MM-DD)
LAT 30:00N
LON 140:00E
Maritime
Grounding
187
0 KTS
Distress alert setup, distress alert updated
18. Open the cover of the [DISTRESS] button on the terminal unit or the Distress
Alert Unit/Received Call Unit IC-305.
19. Press the [DISTRESS] button until the lamp in the button lights continuously
(about four seconds).
The distress alert will not be transmitted until the lamp in the button lights
continuously and the audio alarm sounds. The message “Sending Distress
Alert” appears on the screen while the distress alert is being transmitted.
When you receive acknowledgment of the distress alert from an LES, the
message “Distress Acknowledgement Received” appears on the screen, the
lamp flashes slowly and the audio alarm sounds intermittently. To silence the
audio alarm, press the [F10] key on the keyboard.