9. MAINTENANCE, TROUBLESHOOTING
9-9
9.7 Error Messages
This section describes the more commonly seen error messages and the means
to restore normal operation. If normal operation cannot be restored, contact your
dealer for advice.
9.7.1 Equipment trouble messages
Messages in this category are prefixed with “TROUBLE:”.
Equipment trouble messages
Error Message Meaning Action
ANT power voltage
abnormality.
Antenna power voltage. Have a licensed
radiocommunications
technician check the set.
Carrier power level. Carrier power level too high or
too low.
Have a licensed
radiocommunications
technician check the set.
DISTRESS ALERT
UNIT Fault.
Trouble at Distress Alert
Unit/Received Call Unit IC-305.
Check that the IC-305 is
powered and connected to
the FELCOM.
DMC connection
abnormality.
Trouble at Distress Message
Controller DMC-5.
Check that the DMC-5 is
powered and connected to
the FELCOM.
EEPROM ERROR. EEPROM trouble. Contact a FURUNO agent
or dealer for advice.
ALARM UNIT
Fault.
Trouble at Alarm Unit IC-306. Check that the IC-306 is
powered and connected to
the FELCOM.
Invalid MES ID, This
equipment is
defected. Please
contact FURUNO.
MES ID is corrupted. Have a licensed
radiocommunications
technician check the set.
Synthesizer
UNLOCK.
Synthesizer unlock. Have a licensed
radiocommunications
technician check the set.

Table of Contents

Other manuals for Furuno FELCOM 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 15 and is the answer not in the manual?

Furuno FELCOM 15 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 15
CategoryMarine Radar
LanguageEnglish

Related product manuals