GENERAL
15
PULSE Installaon, Commissioning and Servicing Manual - Revision 19
Sucon System
1 pump and motor per product Dedicated meter for each product hose/nozzle
Standard - sucon head limit 4.0m (petrol @ 25°C @ sea-level) max, includes vercal li and losses in supply pipe lines and ngs
Standard - sucon head limit 5.0m (diesel @ 25°C @ sea-level) max, includes vercal li and losses in supply pipe lines and ngs
Ultra - sucon head limit 3.0m maxiumum eecve sucon head with the T140 only for Ultra/High Diesel ow
Air Separaon
Tatsuno PGS-0257 FP1001 Pumping Unit
Benne T140 Hydrauic High Flow Pumping Unit
Pressure System
Submersible pump unit (STP) in the remote fuel tank - controlled from on-board AC Control system. Minimum 1 STP/product
Inlet manifold pressure 100 - 350kPa max (MUST NOT exceed 350kPa)
Delivery Flow Rate
Standard up to 40L/min Standard nozzle with reduced spout (38L/min target)
Boost buon up to 60L/min Standard nozzle with 19mm standard diesel spout
Diesel High Flow up to 80L/min Nozzle 25mm with 25mm standard spout
Diesel Ultra Flow up to 120+L/min Nozzle 25mm with 25mm standard spout
DEF - Euro5: Trucks up to 40L/min DEF - Euro 6: Passenger cars up to 5L/min (DEF - Diesel Exhaust Fluid)
LPG up to 40L/min Gas Guard GG1DN LPG Nozzle with latching opon
* All quoted delivery ow rates dependent on supply pressure, condion of the underground piping and fuel quality impacts
Metering
Tatsuno FM-1007 Flow Meter
Tatsuno FM-1002 Lobe Meter (Ultra Flow Diesel)
Electronic System
All electronic components located in the hazardous areas (hydraulic cabinet and hose stowage area) are intrinsically safe
All other electronic components are located in the non-hazardous area within the User Interface
Display Total Price 7 Digit Transecve backlit LCD. Limited to MAX $9990.00 by POS protocols
5 or 6 digit opons available
Total Volume 7 Digits Transecve backlit LCD. Limited to MAX 9990.00 litres by POS protocols
5 or 6 digit opons available
Preset 5 or 6 Digit Transecve backlit LCDs. Limited to MAX $9990.00
Unit Price 5 Digit Transecve backlit LCDs
Tote Digital
8 digit totalisator for total volume and dollars per hose
Electro Mechanical 7 digit totalisator for total volume per hose (opon)
Pulser 88918/07434 Intrinsically safe pulser, IECEx cered Ex ib
Forecourt Communicaons PEC Two wire 12V parallel system
Gilbarco Australia Two wire current loop system
Electrical System
Motor Elnor 750W IECEx cered Ex d single phase
Motor Elnor 1500W IECEx cered Ex d single phase (Ultra sucon soluons)
Solenoid Valves ASCO 24VDC proporonal solenoid valve. IECEx cered Ex m
Temperature Range -10°C to +50°C
Electrical Requirements 220-240 VAC
Mechanical System
Hose Elaex 16mm AS 2683 compliant
High Flow Hose Elaex 21mm or 25mm - AS2683 compliant
Ultra, High or Boosted Flow Switch Illuminated buon available on all models with diesel
Nozzle Elaex ZVA Automac Nozzle: ZVA Slimline 2 / ZVA25
Dry-break couplings Elaex SSB16/ SSB25 Straight - Safety Swivel Break at the Nozzle
MAX No. of Products Dispensed L Series: 5 per side C Series: 4 per side
Ethanol, LPG, Biodiesel and DEF capable Yes. (Limits: Ethanol up to E10 or E85. Biodiesel up to B20)
Vapour Recovery opon Yes. Integral with Elaex VR Hoses and Nozzles
Hose Reach L Series: Reach: 3.3m - Hanging hose 4.0m - Retractor slide acvates at 3.3m
C Series:
Reach: 3.8m - Hanging hose 4.5m - Retractor reel acvates at 3.8m
CS Q: Reach: 4.2m - Standard Flexi-arm 5.2m - Extended Flexi-arm
8 PULSE TECHNICAL SPECIFICATIONS