SERVICING
95
PULSE Installaon, Commissioning and Servicing Manual - Revision 19
15.10 PULSE Counted Error Codes
Name Brief Meaning Type Troubleshoong
1 FLUID The oat switch has been
acvated
Hard Check sump for uid. Check uid
switch operaon and connecons
2 POS Lost connecon with POS
during delivery
So Check POS/Forecourt controller
loop connecon and operaon
3 STACK Stack failed to start delivery So Replace stack controller. Check
encoder
4 OVERRUN Pre-set delivery amount has
been exceeded
So Check for leaking valves
5 LPG MTR LPG meter communicaon
error
So Check cable to meter, check
meter has power, etc
6 SECURITY LPG meter security error So Check the security dip switch in
the LPG meter and switch to the
secure posion
7 ENCODER Reverse or unusual fuel
movement detected
So but aer three triggers per
hose a Hard error occurs and on
subsequent restart the aected
hose is disabled
Check encoder, cables, mux,
stack. Check for leaks and leaking
valves
8 XS FLOW Excess LPG ow detected So Check for leaks in LPG system.
May also occur when lling
empty tanks
9 RUN ON Fuel movement detected
aer nozzle hung up
So Check for valve not closing.
Check encoder operaon for false
counng. Check for fuel leaks.
Check nozzle switch operaon
10 LPG COMS LPG communicaon error So Check cable to meter, check
meter has power, etc
11 RATIO Blended delivery outside
acceptable parameters
So but aer three triggers per
hose a Hard error occurs and on
subsequent restart the aected
hose is disabled
Check for large pressure dier-
enals caused by clogged lters.
Test fuel pathways for unusual
ow rates in stack test
12 MUX MUX communicaon inter-
rupted
Logged Check cable to mulplex board
and the barrier board, check mul-
plex board and barriers board
have power, etc
Version 1.20
Key:
Type
Logged = Recorded in the log file only.
Soft = Stops the current delivery on the affected Fuelpoint. These require a nozzle
on the affected Fuelpoint to be hung up twice to clear.
Hard = Stops all deliveries on the pump. This requires a repower to clear.