EasyManua.ls Logo

Gallagher PULSE Series - PULSE Counted Error Codes

Gallagher PULSE Series
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICING
95
PULSE Installaon, Commissioning and Servicing Manual - Revision 19
15.10 PULSE Counted Error Codes
Name Brief Meaning Type Troubleshoong
1 FLUID The oat switch has been
acvated
Hard Check sump for uid. Check uid
switch operaon and connecons
2 POS Lost connecon with POS
during delivery
So Check POS/Forecourt controller
loop connecon and operaon
3 STACK Stack failed to start delivery So Replace stack controller. Check
encoder
4 OVERRUN Pre-set delivery amount has
been exceeded
So Check for leaking valves
5 LPG MTR LPG meter communicaon
error
So Check cable to meter, check
meter has power, etc
6 SECURITY LPG meter security error So Check the security dip switch in
the LPG meter and switch to the
secure posion
7 ENCODER Reverse or unusual fuel
movement detected
So but aer three triggers per
hose a Hard error occurs and on
subsequent restart the aected
hose is disabled
Check encoder, cables, mux,
stack. Check for leaks and leaking
valves
8 XS FLOW Excess LPG ow detected So Check for leaks in LPG system.
May also occur when lling
empty tanks
9 RUN ON Fuel movement detected
aer nozzle hung up
So Check for valve not closing.
Check encoder operaon for false
counng. Check for fuel leaks.
Check nozzle switch operaon
10 LPG COMS LPG communicaon error So Check cable to meter, check
meter has power, etc
11 RATIO Blended delivery outside
acceptable parameters
So but aer three triggers per
hose a Hard error occurs and on
subsequent restart the aected
hose is disabled
Check for large pressure dier-
enals caused by clogged lters.
Test fuel pathways for unusual
ow rates in stack test
12 MUX MUX communicaon inter-
rupted
Logged Check cable to mulplex board
and the barrier board, check mul-
plex board and barriers board
have power, etc
Version 1.20
Key:
Type
Logged = Recorded in the log file only.
Soft = Stops the current delivery on the affected Fuelpoint. These require a nozzle
on the affected Fuelpoint to be hung up twice to clear.
Hard = Stops all deliveries on the pump. This requires a repower to clear.