Index MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 114 ARTDrive V2 series - Instruction Manual
B0E.5M Measured Flux Max [Wb] RW Calc 0.00 - FK V-F-S Full 2900
Value of the maximum Flux.
B0F STARTUP / Drv & Mot config / V/f cfg
B0F.00 V/f voltage [V] RWZ Motr Calc/Calc FK V Easy 3420
Base voltage for the V/f mode. This parameter is set according to motor nominal voltage,
but can be changed to modify V/f characteristic.
B0F.01 V/f frequency [Hz] RWZ Motr 5/Calc FK V Easy 3430
Base frequency for the V/f mode. This parameter is set according to motor nominal
frequency, but can be changed to modify V/f characteristic.
B0F.02 Voltage boost [%] RWS Calc 0.00/0.00 PV V Easy 3400
Torque boost at low speed. It allows to increase the output voltage at zero Hz.
Initialized by autotune procedure
V
B0F.01
f
B0F.00
B0F.02
Figure B0F.02: V/f characteristic
B0F.03 V/f shape N/A RWZ 0 0/3 DP V Easy 3410
It allows to define the V/f curve shape; it can be selected among:
[0]V = freq^1.0 Constant torque requirement accross the whole speed range
[1]V = freq^1.5 Mixed load between type 0 and 3
[2]V = freq^1.7 Mixed load between type 0 and 3
[3]V = freq^2.0 Load where the torque is proportional to the speed squared, for example fans
and pumps
B0F.04 Slip comp [rpm] RWS Calc 0.00/Calc PV V Easy 3531
Compensation of speed drop due to load. Initialized by autotune procedure.
Low values of Slip comp parameter may cause instability.
B0F.05 Slip comp filter [sec] RWS 1 Calc/10 PP V Easy 3541
Slip compensation filter.